| Brief introduction |
|
| XMT -7000 intelligent temperature controllers are the multi-functional regulators adopting the micro processing units. As also adopting the switch power source and Surface Mount Technology(SMT), it is small and has great performance. The special self-diagnosis, self-conditioning and intelligent functions bring good efforts through simple operating. |
|
| Characteristic |
|
| 1.Display pv value and SV value by the high brigh red and grenn double-row digital tube |
|
| 2.Appointed input by sensing signal |
|
| 3.Automatic amend by sensing unit |
|
| 4.Function of second class data lock protection |
|
| 5.Alarm rang:free set the complete range |
|
| 6.Operating power supply:Transformer power supply:AC220V±10%,50/60Hz |
|
| Main technologies indicates |
|
| 1. Input |
|
| Any kind of TC, RTD's standard signal of current and voltage (see the kinds sheet of input) |
|
| 2. Accuracy |
|
| Measure accuracy |
±0.5%FS |
| Cold-end Compensation deviation |
in the range of ±2°C(0~502°C can be amended by the software) |
| Resolving power |
14bit |
| Sampling cycle |
0.5 Sec |
| 3. Display |
|
| PV,SV |
-1999 ~ +1999 |
| Indicatesof output,alarm,self-conditioning |
LED |
| 4. Controlling output |
|
| Relay output |
contact capacity 250VA (resistance load) |
| Voltage pulse output |
0~12V, (suitable for the solid relay SSR) |
| Alarm function output |
2 groups output at most, 12 modes. |
| Capacity of the output contact |
250V AC 3A (resistant load) |
| 5. Setting range |
|
| Setting value (SV) |
Measured Present Value (PV) |
| Proportional band (P) |
0 ~ whole measured range (when set 0, it's ON/OFF control |
| Integral time |
0~3600 Sec (when the time is 0, the function of integral time closed) |
| Derivative time |
0~ 3600 Sec (when the time is 0, the function of differential time closed) |
| Proportional term |
1~100°C Sec |
| Hysteresis loop Width of the phase controlling output |
1~100 (or other pv units) |
| 6. Others |
|
| Insulation resistance |
>500 M (500DC) |
| Insulation strength |
1500VAC/1min |
| Power consumption |
<10VA |
| Using environment |
0~50°C, 30~85% RH no corrosive atmospheres environment |
| Weight |
about 0.5kg |
Смотрите так же другие товары: